Geno™ Type 2 Water | Deionized Water Purification System

Geno™ Deionized (DI) water purification systems for laboratories and hospitals. Produces Type 2 General Laboratory Grade Water.

    • RO sanitization process
    • Up to 25 or 45L/hr production rates
    • Low running costs
    • Easy to change pre-filter and quick-disconnect Endure™ DI Pack
    • Mount on bench, wall or on top of a reservoir
    • Intuitive, icon-based interactive user interface with touchscreen
    • Choice of storage reservoir, 30, 60 or 100 litres
    • Variable permeate flowrate


    Contact Avidity Science.

    POA
    Availability: In stock
    SKU
    GENO-US

    Geno™ - Type 2 Deionized Water At The Rate You Need

    The Geno™ water purification system is a complete, pre-engineered system designed specifically for Type 2 water applications. The reverse osmosis system uses pressure to separate contaminates out of supply water using a semipermeable membrane. The RO water is then fed through ion-exchange resins to deionize the water, creating Type 2 laboratory grade water.

    With the addition of the endure deionization packs, Geno™ takes RO water to the next level of purity. It provides laboratory grade, Type 2 water in two convenient production rates of up to 25 or 45 liters per hour. Select the reservoir size to suit your requirements. 

    Geno™ combines all required technologies to produce Type 2 water in one box. The endure DI packs are simple to change and long lasting.


    Type 2 Water Applications

    Geno™ is suitable for Type 2 / DI water usage of 160 - 320 liters per day.  DI water is suitable for buffer and media production, sample and reagent diluents, general chemistry, protein electrophoresis, histology, cytology, and spectrophotometry.  The integral boost pump simplifies installation and avoids unexpected costs. The system is fed directly from your municipal water supply. 


    What is Deonization?

    Deionization is a process that removes ions from RO water with the use of synthetic resins.  The ions are removed from the water through a series of chemical reactions. These reactions occur as the water passes through the ion exchange resins beads. Gradually, all unwanted ions are replaced by hydrogen and hydroxyl ions which combine to form pure water. Deionization is the only process that can produce the quality required for Type 2 water.


    Avidity Science Geno Environmentally Friendly Water Systems

    Geno™ Technical Specifications

    Type 2 water using reverse osmosis and deionization technology 


    FEATURES AND BENEFITS

    • Produces Type 2 general laboratory grade water
    • Novel recirculation process extends life of RO membrane and DI cartridges
    • RO sanitization process
    • Up to 25 or 45L/hr production rates
    • Low running costs
    • Easy to change pre-filter and quick-disconnect Endure™ DI Pack
    • Mount on bench, wall or on top of a reservoir
    • Intuitive, icon-based interactive user interface with touchscreen
    • Choice of storage reservoir, 30, 60 or 100 litres
    • Variable permeate flowrate


    PRODUCT WATER QUALITY

    MODEL

    DI MAKE UP RATE (@15 °C)

    INORGANICS REJECTION RATE**

    DI QUALITY (@25 °C)

    DISPENSE RATE (@15 °C FROM TANK)*

    TYPICAL TOC REDUCTION***

    RECOMMENDED DAILY USAGE:

    GENO20 Up to 25 L/hr 98 % 1 - 15 MΩ/cm 3 - 7 L/min 96 % 160 L/day
    GENO40 Up to 45 L/hr 98 % 1 - 15 MΩ/cm 3 - 7 L/min 96 % 320 L/day

    * Depending on tank and pump setup

    ** Depending on feedwater impurities

    *** Using tank UV option


    SYSTEM REQUIREMENTS

    FEED WATER

    Pressure Bar 0.1 - 6
    Conductivity μS/cm < 1400
    Temperature °C 4 - 30
    Hardness as CaCO3 ppm < 400
    Free Chlorine ppm < 2
    Colloid Index SDI < 3
    pH Value 4 - 10
    Iron (Total Fe) ppm < 0.1


    UNIT SPECIFICATIONS

    ALL MODELS

    Dimensions (HxWxD) 500 x 490 x 290 mm
    Installed Weight 23 kg
    Power Supply 100 - 240 V ~; 50/60 Hz; 3.0 A (max)
    Power Supply Output 24 VDC, 5.0 A, 120 W (max)
    Operating Temperature °C - 35 °C (max)
    Storage Temperature °C - 35 °C (max)


    UTILITIES & SERVICES

    REQUIREMENTS

    Water Supply Isolated cold-water feed
    Drain Type Sink/Tundish/Standard up-stand with suitable trap
    Drain Flow > 3 L/min


    CONSUMABLES & ACCESSORIES

    PART NUMBER

    DESCRIPTION

    TYPICAL ANNUAL REQUIREMENT

    TC001 Pre-treatment Module 2*
    TC002 Endure™ Purification Pack 1 2
    TC005 Tank Vent Filter 1
    TANK30 30 Litre Tank -
    TANK60 60 Litre Tank -
    TANK100 100 Litre Tank -
    TANK100P-1 100 Litre Tank with Pump - 230 V -
    TANK100P-2 100 Litre Tank with Pump - 110 V -
    AV003 Distribution Pump Kit -
    AV004 Valve Kit for Washing Machine Feed (Single POU) -
    AV006 Wall Mounting Kit -
    AV007 External Pre-filter Housing Kit (Excludes Filter) -
    AV008 Wall Mounting Kit (TANK30) -
    AV009 Wall Mounting Kit (TANK60) -
    AV012 UV Upgrade Kit (TANK30/TANK60/TANK100) -
    AV014 Custom Tank Level Sensor Kit -
    AV016 Valve Kit for Washing Machine Feed (Double POU) -
    AV027 IQOQ Documentation for Geno -
    AV034 RO Sanitising Kit for Duo, Geno and Puro -

    * Depending on Feed water Quality and Usage


    TYPE 2 WATER


    APPLICATIONS

    Buffer & Media Preparations
    Sample Dilution & Reagent Preparation
    Spectrophotometry
    Protein Electrophoresis
    Cytology & Histology
    Glassware Washing & Rinsing

    GENO™ FLOW CHART 

    Avidity Science GENO Water System Flowchart



    RESERVOIRS

     

    WIDTH

    HEIGHT

    DEPTH

    TANK30

    410 mm

    500 mm

    240 mm

    TANK60

    485 mm

    500 mm

    330 mm

    TANK100

    485 mm

    800 mm

    340 mm

    TANK100PUMP*

    485 mm

    800 mm

    340 mm

    *100 litre tank with built-in pump to provide the correct pressure for feeding washing machines, glasswashers and remote points of use.  

    • Including dispense tap on front of the reservoir in the middle or at the bottom
    • 3/4” BSP glass-washer outlet
    • Pressure sensor level control, with a 0-100% contents display
    • 0.2 μm microbiological air vent filter or an optional CO2 filter
    • 30 and 60 litre reservoirs are wall mountable 


    SERVICES REQUIRED

    3/4” BSP isolated cold water feed (washing machine tap/valve)

    240 Volt, 13 Amp sockets

    Drain/up-stand with trap or sink/tundish


    OPTIONAL LEAK DETECTION

    If your water system is in a location where a leak could cause damage or health and safety issues, we recommend that you protect against this possibility by means of a leak detector, or for larger systems a containment bund. Containment bunds, price available on application. The following are available from Avidity Science: 

    PART NO.

    DESCRIPTION

    2084

    Water Guard for small laboratory equipment up to 100L/hr

    00029

    Water Guard for larger equipment with a feed connection up to ¾”

    Write Your Own Review
    You're reviewing:Geno™ Type 2 Water | Deionized Water Purification System