Geno™ Type 2 Water | Deionized Water Purification System

Geno™ Deionized (DI) water purification systems for laboratories and hospitals. Produces Type 2 General Laboratory Grade Water.

 

  • RO sanitization process
  • Up to 25 or 45L/hr production rates
  • Low running costs
  • Easy to change pre-filter and quick-disconnect Endure™ DI Pack
  • Mount on bench, wall or on top of a reservoir
  • Intuitive, icon-based interactive user interface with touchscreen
  • Choice of storage reservoir, 30, 60 or 100 liters
  • Variable permeate flowrate


Contact Avidity Science.

Availability: In stock
SKU
GENO-US

Geno™ - Type 2 Deionized Water At The Rate You Need

The Geno™ water purification system is a complete, pre-engineered system designed specifically for Type 2 water applications. The reverse osmosis system uses pressure to separate contaminates out of supply water using a semipermeable membrane. The RO water is then fed through ion-exchange resins to deionize the water, creating Type 2 laboratory grade water.

With the addition of the endure deionization packs, Geno™ takes RO water to the next level of purity. It provides laboratory grade, Type 2 water in two convenient production rates of up to 25 or 45 liters per hour. Select the reservoir size to suit your requirements. 

Geno™ combines all required technologies to produce Type 2 water in one box. The endure DI packs are simple to change and long lasting.


Type 2 Water Applications

Geno™ is suitable for Type 2 / DI water usage of 160 - 320 liters per day.  DI water is suitable for buffer and media production, sample and reagent diluents, general chemistry, protein electrophoresis, histology, cytology, and spectrophotometry.  The integral boost pump simplifies installation and avoids unexpected costs. The system is fed directly from your municipal water supply. 


What is Deionization?

Deionization is a process that removes ions from RO water with the use of synthetic resins.  The ions are removed from the water through a series of chemical reactions. These reactions occur as the water passes through the ion exchange resins beads. Gradually, all unwanted ions are replaced by hydrogen and hydroxyl ions which combine to form pure water. Deionization is the only process that can produce the quality required for
Type 2 water.


Avidity Science Geno Environmentally Friendly Water Systems

Geno™ Technical Specifications

 

Type 2 water using reverse osmosis and deionization technology 


FEATURES AND BENEFITS

  • Produces Type 2 general laboratory grade water
  • Novel recirculation process extends life of RO membrane and DI cartridges
  • RO sanitization process
  • Up to 25 or 45L/hr production rates
  • Low running costs
  • Easy to change pre-filter and quick-disconnect Endure™ DI Pack
  • Mount on bench, wall or on top of a reservoir
  • Intuitive, icon-based interactive user interface with touchscreen
  • Choice of storage reservoir, 30, 60 or 100 liters
  • Variable permeate flowrate

 

 


PRODUCT WATER QUALITY

MODEL

DI MAKE UP RATE (@15 °C)

INORGANICS REJECTION RATE**

DI QUALITY (@25 °C)

DISPENSE RATE (@15 °C FROM TANK)*

TYPICAL TOC REDUCTION***

RECOMMENDED DAILY USAGE:

GENO20 Up to 25 L/hr 98 % 1 - 15 MΩ/cm 3 - 7 L/min 96 % 160 L/day
GENO40 Up to 45 L/hr 98 % 1 - 15 MΩ/cm 3 - 7 L/min 96 % 320 L/day

* Depending on tank and pump setup

** Depending on feedwater impurities

*** Using tank UV option

 

 


SYSTEM REQUIREMENTS

FEED WATER

 

 
Pressure Bar 0.1 - 6
Conductivity μS/cm < 1400
Temperature °C 4 - 30
Hardness as CaCO3 ppm < 400
Free Chlorine ppm < 2
Colloid Index SDI < 3
pH Value   4 - 10
Iron (Total Fe) ppm < 0.1

 


UNIT SPECIFICATIONS

ALL MODELS

 

Dimensions (HxWxD) 500 x 490 x 290 mm
Installed Weight 23 kg
Power Supply 100 - 240 V ~; 50/60 Hz; 3.0 A (max)
Power Supply Output 24 VDC, 5.0 A, 120 W (max)
Operating Temperature °C - 35 °C (max)
Storage Temperature °C - 35 °C (max)

 


UTILITIES & SERVICES

REQUIREMENTS

 

Water Supply Isolated cold-water feed
Drain Type Sink/Tundish/Standard up-stand with suitable trap
Drain Flow > 3 L/min

 


CONSUMABLES & ACCESSORIES

PART NUMBER

DESCRIPTION

TYPICAL ANNUAL REQUIREMENT

TC001 Pre-treatment Module 2*
TC002 Endure™ Purification Pack 1 2
TC005 Tank Vent Filter 1
TANK30 30 Liter Tank -
TANK60 60 Liter Tank -
TANK100 100 Liter Tank -
TANK100P-1 100 Liter Tank with Pump - 230 V -
TANK100P-2 100 Liter Tank with Pump - 110 V -
AV003 Distribution Pump Kit -
AV004 Valve Kit for Washing Machine Feed (Single POU) -
AV006 Wall Mounting Kit -
AV007 External Pre-filter Housing Kit (Excludes Filter) -
AV008 Wall Mounting Kit (TANK30) -
AV009 Wall Mounting Kit (TANK60) -
AV012 UV Upgrade Kit (TANK30/TANK60/TANK100) -
AV014 Custom Tank Level Sensor Kit -
AV016 Valve Kit for Washing Machine Feed (Double POU) -
AV027 IQOQ Documentation for Geno -
AV034 RO Sanitizing Kit for Duo, Geno and Puro -

* Depending on Feed water Quality and Usage


TYPE 2 WATER


APPLICATIONS

Buffer & Media Preparations
Sample Dilution & Reagent Preparation
Spectrophotometry
Protein Electrophoresis
Cytology & Histology
Glassware Washing & Rinsing

GENO™ FLOW CHART 

Avidity Science GENO Water System Flowchart

 


RESERVOIRS

 

 

 

WIDTH

HEIGHT

DEPTH

TANK30

410 mm

500 mm

240 mm

TANK60

485 mm

500 mm

330 mm

TANK100

485 mm

800 mm

340 mm

TANK100PUMP*

485 mm

800 mm

340 mm

 

*100 liter tank with built-in pump to provide the correct pressure for feeding washing machines, glasswashers and remote points of use.  

 

  • Including dispense tap on front of the reservoir in the middle or at the bottom
  • 3/4” BSP glass-washer outlet
  • Pressure sensor level control, with a 0-100% contents display
  • 0.2 μm microbiological air vent filter or an optional CO2 filter
  • 30 and 60 liter reservoirs are wall mountable 

 

 


OPTIONAL LEAK DETECTION

 

If your water system is in a location where a leak could cause damage or health and safety issues, we recommend that you protect against this possibility by means of a leak detector, or for larger systems a containment bund. Containment bunds, price available on application. The following are available from
Avidity Science: 

 

PART NO.

DESCRIPTION

2084

Water Guard for small laboratory equipment up to 100L/hr

00029

Water Guard for larger equipment with a feed connection up to ¾”