Geno™ Type 2 Water | Deionised Water Purification System

Geno™ Deionised (DI) water purification systems for laboratories and hospitals. Produces Type 2 General Laboratory Grade Water

  • Low running costs
  • Up to 50% water recovery rate
  • Easy to change consumables with realistic costs
  • Bench, wall or reservoir top mounting
  • Intuitive, icon-based interactive user interface with touchscreen
  • Choice of storage reservoir, 30, 60 or 100 litres
  • Choice of production rates depending on how much water you need during the day
  • Integral boost pump

Download Avidity Science Lab Water Brochure

Request a Quote

 

Availability: In stock
SKU
GENO

Geno™ - Delivering Type 2 Deionised Water At The Rate You Need

The Geno™ water purification system takes RO water to the next level of purity, providing DI laboratory grade water in three convenient production rates of 10, 20 or 50 litres per hour. The Geno™ combines all the latest technologies to produce Type 2 DI water. The Endure DI packs are simple to change and long lasting.


Type 2 Water Applications

The Geno™ is suitable for DI water usage of 10-400 litres per day. Type 2 DI water is suitable for:

  • Buffer and Media Production
  • Sample Dilution and Reagent Preparation
  • Spectrophotometry
  • Protein Electrophoresis
  • Cytology & Histology
  • Glassware Washing & Rinsing

Features 

  • Low running costs
  • Easy to change consumables with realistic costs
  • Bench, wall or reservoir top mounting
  • Choice of storage reservoir, 30, 60 or 100 litres
  • Choice of production rates depending on how much water you need during the day
  • Integral boost pump

The integral boost pump avoids unexpected costs by providing an uninterrupted feed water supply. The Geno™ is fed directly from your mains water supply.


How does Deionisation Work?

Deionisation is a process that removes ions from RO water with the use of synthetic resins. The ions are removed from the water through a series of chemical reactions. These reactions occur as the water passes through the ion exchange resins beads. Gradually, all unwanted ions are replaced by hydrogen and hydroxyl ions which combine to form pure water. Deionisation is the only process that can produce the quality required for Type 2 water.

Geno saves the environment

How old is your Lab Water System?

Geno™ Technical Specifications

Type 2 water using reverse osmosis and deionisation technology 

  • 1-15 MΩ-cm
  • Type 2 Water Quality general laboratory grade water
  • >50% recovery of RO water
  • Novel recirculation process extends life of RO membrane and DI cartridges
  • TOC <50ppb
  • Operates at 0.1-6 bar feed water pressure
  • Up to 98% rejection of inorganics
  • Compact design
  • Wall mounting brackets included
  • Bench, reservoir-top or wall mounting
  • Excellent monitoring of conductivity
  • SD Card interface
  • Choice of 30/60/100 litre capacity reservoir               


PRODUCT WATER QUALITY

MODEL

DI MAKE UP RATE (@15°C)

INORGANICS REJECTION RATE**

DI QUALITY (@25°C)

DISPENSE RATE (@15°C FROM TANK)*

TYPICAL TOC REDUCTION***

GENO10 10L/hr 98% 1 - 15MΩ-cm 3 - 7L/min 96%
GENO20 20L/hr 98% 1 - 15MΩ-cm 4 - 7L/min 96%
GENO50 50L/hr 98% 1 - 15MΩ-cm 5 - 7L/min 96%

* Depending on tank and pump setup

** Depending on feedwater impurities

*** Using tank UV option


SYSTEM REQUIREMENTS

FEED WATER

Pressure Bar 0.1 - 6
Conductivity μS/cm <1400
Temperature °C 4 - 30
Hardness as CaCO3 ppm <400
Free Chlorine ppm <2
Colloid Index SDI <3
pH Value 4 - 10
Iron (Total Fe) ppm <0.1


UNIT SPECIFICATIONS

ALL MODELS

Dimensions (HxWxD) 500 x 490 x 290mm
Installed Weight 23kg
Power Supply 100 - 240V ~; 50/60Hz; 3.0A (max)
Power Supply Output 24VDC, 5.OA, 120W (max)
Operating Temperature 4°C - 35°C (max)
Storage Temperature 4°C - 35°C (max)


UTILITIES & SERVICES

REQUIREMENTS

Water Supply Isolated cold-water feed
Drain Type Sink/Tundish/Standard up-stand with suitable trap
Drain Flow >3L/min


CONSUMABLES & ACCESSORIES

PART NUMBER

DESCRIPTION

TYPICAL ANNUAL REQUIREMENT

TC001 Pre-treatment Module 2
TC002 Endure™ Purification Pack 1 2
TC005 Tank Vent Filter 1
TANK30 30 Litre Tank -
TANK60 60 Litre Tank -
TANK100 100 Litre Tank -
TANK100P-1 100 Litre Tank with Pump - 230V -
TANK100P-2 100 Litre Tank with Pump - 110V -
AV004 Valve Kit for Washing Machine Feed (Single POU) -
AV006 Wall Mounting Kit -
AV007 External Pre-filter Housing Kit (Excludes Filter) -
AV016 Valve Kit for Washing Machine Feed (Double POU) -


TYPE 2 WATER

APPLICATIONS

Buffer & Media Preparations
Sample Dilution & Reagent Preparation
Spectrophotometry
Protein Electrophoresis
Cytology & Histology
Glassware Washing & Rinsing


GENO™ FLOW CHART 

Avidity Science GENO Water System Flowchart



RESERVOIRS

 

WIDTH

HEIGHT

DEPTH

TANK30

410mm

500mm

240mm

TANK60

485mm

500mm

330mm

TANK100

485mm

800mm

340mm

TANK100PUMP*

485mm

800mm

340mm

*100 litre tank with built-in pump to provide the correct pressure for feeding washing machines, glasswashers and remote points of use.  

  • Including dispense tap on front of the reservoir in the middle or at the bottom
  • 3/4” BSP glass-washer outlet
  • Pressure sensor level control, with a 0-100% contents display
  • 0.2μm microbiological air vent filter or an optional CO2 filter
  • 30 and 60 litre reservoirs are wall mountable 


SERVICES REQUIRED

3/4” BSP isolated cold water feed (washing machine tap/valve)

240 Volt, 13 Amp sockets

Drain/up-stand with trap or sink/tundish


OPTIONAL LEAK DETECTION

If your water system is in a location where a leak could cause damage or health and safety issues, we recommend that you protect against this possibility by means of a leak detector, or for larger systems a containment bund. Containment bunds, price available on application. The following are available from Avidity Science: 

PART NO.

DESCRIPTION

2084

Water Guard for small laboratory equipment up to 100L/hr

00029

Water Guard for larger equipment with a feed connection up to ¾”

  1. DI Storage Tanks

    Fully drainable RO and DI water storage tanks

    • 30 litre
    • 60 litre
    • 100 litre

    Download Lab Water System Brochure

    Request a Quote

    POA
  2. Laboratory Water Consumables

    Avidity Science supply consumables for all types of laboratory water systems including:

    • Pre-treatment cartridges
    • RO cartridges
    • DI cartridges
    • UV lamps
    • Point of use filters

    Download Lab Water System Brochure

    Request a Quote

    POA
Write Your Own Review
You're reviewing:Geno™ Type 2 Water | Deionised Water Purification System