Duo™-i Type 2 and Type 1 | Deionized and Ultrapure Water System

The Duo™-i Type 2 and Type 1 Laboratory Water Purification System is fully integrated to produce up to 30 L/hr of Type 2 water directly from tap-water.
It dispenses up to 2 L/min of both Type 2 deionized water and Type I ultrapure water from a flexible dispenser. Real-time water quality and operating conditions are displayed on the dispensing interface.

  • Dispense Type 2 and Type 1 water from the remote dispensers
  • Unique twin pass RO technology ensures enhanced DI cartridge capacity
  • Data capture with printable option
  • Specific cartridges for your critical applications
  • Integrated Water Leak Protection
  • Adjustable dispenser
  • Cartridge traceability with data tag
  • Interactive 7” touch screen
  • Color coded dispensing stations with flexible dispensing options
  • Fully integrated pretreatment module included
  • Pretreatment module comes standard with a 5-micron particle filter and an
    activated carbon filter

 

Download the Avidity Science Lab Water Brochure

Request a Quote

Availability: In stock
SKU
Duo-i-II.I-1

Intelligent Dual Quality Water Purification System

The Duo™-i Type 2 and Type 1 Laboratory Water Purification System is fully integrated to produce up to 30 L/hr of Type 2 water directly from tap water. It dispenses up to 2 L/min of both Type 2 deionized water and Type I ultrapure water from a flexible dispenser. Real-time water quality and operating conditions are displayed on the dispensing interface. A compact dispensing stand (28x30 cm) offers true flexibility to users by maximizing bench space and locating the dispenser at the most convenient point of use.

This state-of-the-art platform has been designed to work with your unique feed water conditions, application needs and functional requirements.
It maximizes purification power at each stage so that the pure and ultrapure water outputs are consistently high in quality. In addition, system monitoring and water leak protection functions offer peace of mind for your laboratory deionized and ultrapure water supply.


Type 2 / DI Water Applications

Type 2 Water output from the Duo™-i system meets or exceeds Type 2 water standards as specified by ASTM, CAP, ISO 3696, CLSI, JIS K0557 and Purified Water as described in USP, EP and ChP. Type 2 water is required for more sensitive laboratory applications such as:

  • Buffer and media preparations
  • Sample dilution and reagent preparation
  • Spectrophotometry
  • Protein electrophoresis
  • Cytology and histology
  • Glassware washing and rinsing

Type 1 / Ultrapure Water Applications

Type 1 Water from the Duo™-i system meets or exceeds Type 1 water standards as specified by ASTM, CAP, ISO 3696, CLSI, JIS K0557 and high-purity water as described in USP, EP and ChP. Type 1 water is required for critical laboratory applications such as:

  • Analytical instrumentations: HPLC, UPLC, AA, ICP, LC-MS, GC-MS, ICP-MS, Ion Chromatography, Electrochemistry, Particle Counter, TOC Analysis
  • Life science instrumentations: PCR, DNA sequencing, electrophoresis
  • Preparations for cell culture, molecular biology and monoclonal antibody applications

Features

Integrated Reverse Osmosis Technologies

  • Patented 2-stage reverse osmosis technology enables superior and stable output quality. Output conductivity of 5 μs/cm is typical from tap water as challenging as 2,000 μs/cm
  • Superior RO purification with up to 99% ion rejection rate. This improves life expectancy of DI cartridges and final filters

Flexible dispensing options

Draw Type II water in three ways: directly from the reservoir tap, from a flexible dispenser on the system, or from two additional remote dispensers each placed up to 2.9m away (up to 5.8m in serial).

  • Real-time Resistivity and Total Organic Carbon (TOC) levels are monitored and displayed on screen
  • Dispense rates of > 2 L/min from the tap, or up to 2 L/min from the remote dispenser, ensure > 120 liters availability for peak hour usage
  • Routine system control functions are fully available on the dispenser including “Print Report” for Good Laboratory Practices. This allows maximum bench space utilization. For example, main system, pre-treatment module and reservoir may all be placed under the bench

Choice of final filters to match your application needs:

  • 0.2 μm for bacteria removal
  • 0.1 μm for particulate removal
  • Positively-charged capsule for RNases, DNases and endotoxin removal

Integrated controls

Enables Type II water to be available from the reservoir. Water quality is maintained by optimizing re-circulation, UV sterilization and vent filtration to minimize re-contamination from CO2, volatile organic compounds, bacteria and particles


Integrated Pre-treatment Module

  • Integrated controls on inlet water pressure and monitoring of flow rates to optimize system operations. Optional booster pump available
  • 3.2” screen displays color-coded operating condition of each component
  • Choice of cartridges based on local tap water condition:
    - Silt Density Index (SDI)
    - Chlorine
    - Bacterial
  • IC chip onboard the cartridges ensures proper installation and operation
  • Easy cartridge replacement

Integrated Reservoir

  • Reservoir controls such as UV exposure timing and conductivity levels are integrated with the main system
  • Vent filter is fitted to reduce environmental contaminants such as CO₂, particles, bacterial and volatile organic compounds
  • Dual level sensing mechanism offers additional system protection when water exceeds critical levels (10% and 110%)

Integrated Polishing Technologies

  • Choice of deionization cartridges with IC tag to meet your applications:
    - Standard high volume polishers
    - Low TOC for sensitive analysis
    - Low Boron for ICP analysis
  • UV technology offers effective oxidation of organic materials and enables rapid water quality recovery upon system re-starts
  • Total Organic Carbon (TOC) monitoring option offers reliable real time results

Integrated System Monitoring

  • Complete monitoring of conductivity, pressure and flow rate at up to 6 stages
  • System conditions are visibly displayed with graphics and color codes
  • Automated disinfection processes ensure complete system sanitization
  • Multiple data management options including RS232 and SD card

Integrated Water Leak Protection

  • Unique base cover channels any potential water leaks to a drainage point. A leak sensor located at the drainage point will detect presence of water droplet 1 mm from the discharge point
  • An additional leak sensor may be placed inside the pre-treatment module

Operating Screen provides comprehensive operating parameters at one glance:

  • Water quality data from dual output: conductivity, TOC, temperature and dispensing rate
  • Reservoir water level
  • On-line alerts

7” touch screen offers friendly and intuitive user experience:

  • “Touch” sequences similar to smart phones allowing new users to operate with ease
  • Color-coding (Red, Amber, Blue) and Flashing indicators offer guidance to any non-routine actions needed and their urgency/criticality
  • Unmatched “width” and “depth” of system control

8 Displayed languages available including English, French, German, Spanish, Portuguese, Chinese, Japanese, or Korean

Monitor screen provides scientific criteria for consumables management based on:

  • Flow rate and pressure sensing
  • Usage time
  • Water quality monitoring

Duo™-i Type 2 and Type 1 Technical Specifications

Deionized and 18.2 MΩ·cm Type 1 Water System

Fully integrated laboratory water purification system which can produce up to 30 L/hr of Type 2 water directly from tap water. It dispenses up to 2 L/min of both Type 2 deionized water and Type I ultrapure water from a flexible dispenser. Real-time water quality and operating conditions are displayed on the dispensing interface. A compact dispensing stand (28x30cm) offers true flexibility to users to maximize bench space utilization and to locate the dispenser at the most convenient point of use.

Click here to view the Technical Specifications